Wieland safe HTL encoder SAFE HTL ENCODER SENC-58S10HTL1024A | R1.450.1050.0
$3,176.00

16 People watching this product now!

Specification

Attribute Value
ECLASS 11: 27272500
ECLASS 8.1: 27272590
ETIM 9.0: EC001486
ETIM 8.0: EC001486
ETIM 7.0: EC001486
ETIM 6.0: EC001486
ETIM 5.0: EC001486
ROHS conformity status: Compliant
REACH-SVHC conformity status: Compliant
Housing material: Die-cast zinc
Weight: 300g
Degree of protection (IP): IP65
Short-circuit Protective Device: Yes
Category (ISO 13849-1): 4
PL (ISO 13849-1): Level e
SILCL(IEC 62061): SIL3
PFHd(High demand mode): 7.53E-10 1/h
HFT: 1
TM: 20a
Nominal voltage: 24V
Operating voltage min.: 11V
Operating voltage max.: 30V
Galvanic Isolation: No
Rated Current: 100mA
Ambient temperature min.: -20°C
Ambient temperature max.: 85°C
Storage temperature / transport min.: -20°C
Storage temperature / transport max.: 85°C
Standards: IEC 61508, IEC 13849-1, IEC 61800-5-2, IEC 62061
PFDd(Low demand mode): 0.000066
DC: 0.99
Mttfd: 1515a
Shaft material: AISI 303 stainless steel
Bearing type: Series 6800 – sealed
Mechanical life time: >29.7 *10^9 rotations/ 82365 hours
Output signal: Digital HTL-Signal (11-30V DC)
Pin coding: A,A/,B,B/ for safety incremental Pulses
Color-coding encoder cable: Agrey,A/pink,Bbrown,B/green,Ored,O/black,+Vblue and green/brown, 0Vwhite und white/green
Resolution: 360 ppm
Reverse Polarity Protection: Yes
PFD avg. speed monitoring for 40°C: 0.000066
PFH speed monitoring for 40°C: 0.000000000753
MTTFd speed monitoring for 40°C: 1515
DCavg speed monitoring for 40°C: 0.99
Mission time speed monitoring for 40°C: 20a
PFD avg. speed monitoring for 80°C: 0.000297
PFH speed monitoring for 80°C: 0.000000000753
MTTFd speed monitoring for 80°C: 336
DCavg speed monitoring for 80°C: 0.99
Mission time speed monitoring for 80°C: 20a
PFD avg. position monitoring for 40°C: 0.000066
PFH position monitoring for 40°C: 0.000000000753
DCavg position monitoring for 40°C: 0.99
Mission time position monitoring for 40°C: 20a
PFD avg. position monitoring for 80°C: 0.000297
PFH position monitoring for 80°C: 0.00000000339
DCavg position monitoring for 80°C: 0.99
Mission time position monitoring for 80°C: 20a
PL category: PLe/Kat4